PVC sheathed copper mineral insulated creative volume control speaker cable
PVC sheathed copper mineral insulated creative volume control speaker cable
  • >= 1000  Meter US $0.66
Capacité de fourniture:
200000 Meter/Meters per 0
Port:
Qingdao/Ningbo/Shanghai
E-mail:
Quantité:
Meter
  • Produit Détails
  • Présentation d'entreprise
Détails Rapides
Lieu d'origine:
China (Mainland)
Nom de Marque:
Numéro de modèle:
BTTQ BTTVQ KVV,KVVP2.KVV32
Emballage & Livraison
In coils, wooden drums, steel drums or steel-wooden drums. 
We could producing according to the customers' requirements.
Produit Description

Product Description

Product introduction

Conductor

• Solid copper

Insulation

• Mineral (MgO) insulation material

Sheath

• Copper Sheath

Model number:MI cable copper conductor mineral insulation fireproof cable BTTZ

Characteristics of BTTZ

1.Heat resistance: The cable can endure flame at 950-1000℃ for 3 hour so as to maintain the circuit integrity.

2.Conductor consists of stranded multiple copper wires, featuring small impedance, large ampacity and flexibility.

3.Insulation consists of heat resistant (above 1300℃)inorganic mineral insulating tapes wound around the conductor, 

featuring even insulation thickness,high AC voltage withstand,high resistance to electrical and heat aging and long service life.  

4.Metal sheath is a corrugated copper sheath (resistant to 1083℃)which prevents the insulation from being loose or 

burned under fire conditions and thus maintain the circuit integrity.

 20150413223756625_副本.jpg

Test standard fire test

Test project

BS6387

GB/T 12666.6

IEC331

Burn

A(Level A): 650±40℃,180min

A(Type A):

750,3h

B(Level B): 750±40,180min

950~100090min

C(Level C): 950±40,180min

B(Type B):

S(Level S): 950±40,20min

750℃~850℃90min

Spray

W(Level W): 650±40℃

No

No

Fire 15min,

Fire again and spray15min

burns for 15min, then

burns again and sprays 15min

Mechanical impact

X(Level X): 650±40,15min

No

No

 Y(Level X): 750±40,15min

Z(Level Z ): 950±40,30 times within 15min

APPLICATIONS

Mineral insulation cable are primarily used in conduit or recognized raceways for services, feeders, and branch

 circuit wiring. Mineral insulation cable may be used at temperatures not to exceed 70  . Voltage rating for

 Mineral Insulation Cable is 450/750V.


Packaging & Shipping

In coils, wooden drums, steel drums or steel-wooden drums. 
We could producing according to the customers' requirements.

2_副本.jpg

Company Information

IMG_4560_副本_副本.jpg

IMG_3359_副本.jpg



Envoyer un message à ce fabricant
E-mail:
Message:
Votre message doit être composé de 20-8000 caractères
 

© 2015 - 2024, wfdbn.com All rights reserved.